Our website uses necessary cookies to enable basic functions and optional cookies to help us to enhance your user experience. Learn more about our cookie policy by clicking "Learn More".
Accept All Only Necessary Cookies
Transformer Spray design आइकन

1.0 by FrankEngineer


Dec 18, 2015

Transformer Spray design के बारे में

पानी के लिए मानक अग्नि सुरक्षा के लिए तय की व्यवस्था का छिड़काव करें।

The Standard for Water Spray Fixed Systems for Fire Protection, formerly Water Spray Nozzles and

Extinguishing Systems, first prepared by the Committee on Manufacturing Hazards, was tentatively adopted in 1939, with final adoption in 1940. Subsequently, this standard was placed under the jurisdiction of the Committee on Special Extinguishing Systems, and a new edition was adopted in 1947. In 1959, the committee organization was further changed to place primary responsibility in the hands of the Committee on Water Spray, under the general supervision of the General Committee on Special Extinguishing Methods. In 1966, the General Committee on Special Extinguishing Methods was discontinued, and the Committee on

Water Spray was constituted as an independent committee. Revised editions were presented

in 1969, 1973, 1977, 1979, and 1982

.

Download Manule Link:

https://drive.google.com/file/d/0BxaWWGlfYY6NQUk1SGE1UkwtWnM/view?usp=sharing

1.1.1 This standard provides the minimum requirements for the design, installation, and system acceptance testing of water spray fixed systems for fire protection service and the minimum requirements for the periodic testing and maintenance of ultra-high-speed water spray fixed systems.

1.1.2* Water spray fixed systems shall be specifically designed to provide for effective fire control, extinguishment, prevention, or exposure protection.

1.1.3* This standard shall not apply to water spray protection

from portable nozzles, sprinkler systems, monitor nozzles, water

mist suppression systems, explosion suppression, or other means

of application covered by other standards of NFPA.

1.2 Purpose. The purpose of this standard shall be to provide

the minimum requirements for water spray fixed systems based

on sound engineering principles, test data, and field experience.

1.3 Application.

1.3.1 Water spray is applicable for protection of specific hazards

and equipment and shall be permitted to be installed independently of, or supplementary to, other forms of fire protection

systems or equipment.

1.3.2 Water spray protection is acceptable for the protection

of hazards involving each of the following groups:

(1) Gaseous and liquid flammable materials

(2) Electrical hazards such as transformers, oil switches, motors, cable trays, and cable runs

(3) Ordinary combustibles such as paper, wood, and textiles

(4) Certain hazardous solids such as propellants and pyrotechnics

(5) Vapor mitigation

1.4 Retroactivity. The provisions of this standard reflect a consensus of what is necessary to provide an acceptable degree of

protection from the hazards addressed in this standard at the

time the standard was issued.

1.4.1 Unless otherwise specified, the provisions of this standard shall not apply to facilities, equipment, structures, or installations that existed or were approved for construction or

installation prior to the effective date of the standard. Where

specified, the provisions of this standard shall be retroactive.

1.4.2 The retroactive requirements of this standard shall be permitted to be modified if their application clearly would be impractical in the judgment of the authority having jurisdiction, and only where it is clearly evident that a reasonable degree of safety is provided.

1.5 Equivalency. Nothing in this standard is intended to prevent the use of systems, methods, or devices of equivalent or superior quality, strength, fire resistance, effectiveness, durability, and safety over those prescribed by this standard. Technical documentation shall be submitted to the authority having jurisdiction to demonstrate equivalency. The system, method, or device shall be approved for the intended purpose by the authority having jurisdiction.

Function

1. Method Design

2. Number Sprinkler Design

3. Area Calculate

4. Flow Sprinkler Calculate

5. Pressure & Flow Sprinkler Calvulate

6. Frictional Loss Calculate

7. Table For Design

8. Graph For Design

अनुवाद लोड हो रहा है...

अतिरिक्त ऐप जानकारी

नवीनतम संस्करण

निवेदन Transformer Spray design अपडेट 1.0

Android ज़रूरी है

2.2

श्रेणी

शिक्षा ऐप

अधिक दिखाएं

नवीनतम संस्करण 1.0 में नया क्या है

Last updated on Dec 18, 2015

Minor bug fixes and improvements. Install or update to the newest version to check it out!

अधिक दिखाएं

Transformer Spray design स्क्रीनशॉट

पिछले 24 घंटों में लोकप्रिय लेख

टिप्पणी लोड हो रहा है...
APKPure की सदस्यता लें
सर्वश्रेष्ठ एंड्रॉइड गेम और ऐप्स के शुरुआती रिलीज, समाचार और गाइड तक पहुंचने वाले पहले व्यक्ति बनें।
जी नहीं, धन्यवाद
साइन अप करें
सफलतापूर्वक सब्सक्राइब!
अब आप APKPure की सदस्यता ले रहे हैं।
APKPure की सदस्यता लें
सर्वश्रेष्ठ एंड्रॉइड गेम और ऐप्स के शुरुआती रिलीज, समाचार और गाइड तक पहुंचने वाले पहले व्यक्ति बनें।
जी नहीं, धन्यवाद
साइन अप करें
सफलता!
अब आप हमारे न्यूज़लेटर की सदस्यता ले चुके हैं।